-40%
Electrodes Welding Rod Parts For S178A S153A S123C Practical High Quality
$ 5.5
- Description
- Size Guide
Description
Product DescriptionElectrodes Welding Rod Parts For S178A S153A S123C Practical High Quality
Warm Tips:
In the process of replacing the electrode head, in case of damage, avoid the electrode from falling into the machine, and replace the electrode after the arc position is calibrated.
Features:
*100% brand new and high quality
*Made of high quality material, durable and practical to use
*Made of high-quality materials, durable
*Suitable for electric welding machine battery
*Fitel S178A S153A S123C-A/B Welding Rod Fiber Optic Fusion Splicer
Specifications:
*Applicable models: S178
*Discharge times:> 4800 times
*Loss: <0.02dB
*Applicable models: (Fitel) S178A, S153A, S123C-A, S123-B, S123M4-A, S123M4-B / 123M12
How to replace the electrode:
*First of all, you must confirm that the welding machine is in the closed state, remove the electrode chamber protective cover and loosen the fixed electrode screw, and then remove the electrode; then loosen the top wire of the lower electrode and remove the lower electrode.
*Secondly, the installation, operation steps and electrode disassembly method of the new electrode can be carried out. The tip of the two electrode tips is: 2.6 0.2 mm.
*Finally, during the assembly process, do not touch the electrode tip to prevent damage to the electrode and avoid damage to the inside of the machine. After replacing the electrode, the arc position should be calibrated.
Electrode cleaning and arc calibration:
*After the installation is complete, turn on the power switch of the welding machine on the 1 electrode.
*The welder enters the initial screen, press the menu button to enter the menu.
*Use the cursor to find the repair point of the mobile machine, put in the clean electrode, and after confirmation, the machine will automatically discharge the clean and aging electrode.
*After the left/right fiber is installed, the position of the arc must be found by moving the cursor. By operating the end face of the fiber and the two electrode heads to maintain the position of the three-point line, the machine will conduct a discharge test, which can be adjusted according to the actual situation .
*Finally, press the menu button, and then press.
Package Contents:
1 pair of electrodes
Note:
1. The real color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.
2. Please allow slight manual measurement deviation for the data.
Payment
We accept payment via Paypal only.
Payment must be completed within 5 days. If you have any problems about payment, please contact us via ebay message.
Delivery details
We only
ship to confirmed Paypal addresses.
Please comfirm that your paypal address is in line with your shipping address.
Please kindly note that
the c
ombined shipping
is not provided
because the shipping fee is calculated by weight. Also, the each additional item means
exactly
the the same color and size.
It takes about
7
-15 working days to US; about 10-30 working days to other countries.
Transit time may be a little delayed because of the
bad
weather and customs
inspection
. If you
do
not receive your
item
within 30 working days since payment finished, please contact us immediately for further assistance.
Contact us
We strive for 100% customer satisfaction! Positive Feedback is very important to us. If you have any questions,
p
lease feel free to contact us via "Ask seller a question" . We will reply your email within 24
working hours.
On Jul-14-21 at 04:57:07 PDT, seller added the following information: